<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" ID="3584">
<titleInfo>
<title><![CDATA[Dental Journal Majalah Kesehatan Gigi (Vol.57 Issue 4 December 2024)]]></title>
</titleInfo>
<name type="Personal Name" authority="">
<namePart>Universitas Airlangga</namePart>
<role><roleTerm type="text">Pengarang</roleTerm></role>
</name>
<typeOfResource manuscript="yes" collection="yes"><![CDATA[mixed material]]></typeOfResource>
<genre authority="marcgt"><![CDATA[bibliography]]></genre>
<originInfo>
<place><placeTerm type="text"><![CDATA[]]></placeTerm></place>
<publisher><![CDATA[]]></publisher>
<dateIssued><![CDATA[2024]]></dateIssued>
<issuance><![CDATA[monographic]]></issuance>
<edition><![CDATA[0]]></edition>
</originInfo>
<language>
<languageTerm type="code"><![CDATA[en]]></languageTerm>
<languageTerm type="text"><![CDATA[English]]></languageTerm>
</language>
<physicalDescription>
<form authority="gmd"><![CDATA[]]></form>
<extent><![CDATA[21 x 29 cm ; 322 Hal]]></extent>
</physicalDescription>
<note>ABSTRACT  Background: In  digital  dentistry, the  intraoral  scanner  (IOS)  is the  primary  data-collecting  device.  The  data  must  be  accurate  to prevent undesirable stresses and technological difficulties resulting from prosthetic misfits. The span length of restorations influences the accuracy of IOS impressions.Purpose: This research aimed to compare the accuracy of virtual models scanned by different IOSs to determine whether jaw curvature and inter-implant distance affect accuracy. Methods: Four mandibular edentulous models were prepared by replacing the site of the missing tooth with an implant. The prepared holes were drilled at 7mm, 14mm, 21mm, and 28mm. Five scans for each model were taken with a desktop laboratory scanner as a reference model and with Trios3Shape and 3Disc Heron IOSs to evaluate trueness and precision (T&P). The scans were saved as standard triangulation language files and statistically analyzed at a level of significance (P ≤ 0.05). Results: There was a significant difference between the IOSs in inter-implant distances (P < 0.05). The greatest distortion was reported in the 21mm and 28mm groups for both scanners (P ≤ 0.05), while the lowest distortion was  observed  in  the  7mm  and  14mm  groups  for  the  Trios3Shape  scanner. Conclusion: Jaw  curvature  and  inter-implant  distance impacted the accuracy of the IOS. Distortion and reduced reproducibility of T&P increased with jaw curve and inter-implant distance. The Trios3Shape IOS showed maximum accuracy at 7mm and 14mm inter-implant distances, while the 3Disc Heron IOS produced significant distortion of trueness at 21mm and 28mm inter-implant distances.</note>
<subject authority=""><topic><![CDATA[Keperawatan Gigi]]></topic></subject>
<classification><![CDATA[023 JI.DEN d(57) / 4 2024]]></classification><identifier type="isbn"><![CDATA[19783728/24429740]]></identifier><location>
<physicalLocation><![CDATA[REPOSITORY Politeknik Kesehatan Kemenkes Jakarta I]]></physicalLocation>
<shelfLocator><![CDATA[023 JI.DEN d(57) / 4 2024]]></shelfLocator>
<holdingSimple>
<copyInformation>
<numerationAndChronology type="1"><![CDATA[T202423]]></numerationAndChronology>
<sublocation><![CDATA[Rak Jurusan Kesehatan Gigi Poltekkes Kemenkes Jakarta I (023 JI.DEN 2024)]]></sublocation>
<shelfLocator><![CDATA[023 JI.DEN d(57) / 4 2024]]></shelfLocator>
</copyInformation>
</holdingSimple>
</location>
<slims:image><![CDATA[cover_2024_v.57_ise_4.jpg.jpg]]></slims:image>
<recordInfo>
<recordIdentifier><![CDATA[3584]]></recordIdentifier>
<recordCreationDate encoding="w3cdtf"><![CDATA[2025-03-03 10:27:24]]></recordCreationDate>
<recordChangeDate encoding="w3cdtf"><![CDATA[2025-03-04 09:46:18]]></recordChangeDate>
<recordOrigin><![CDATA[machine generated]]></recordOrigin>
</recordInfo></mods></modsCollection>