<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" ID="3534">
<titleInfo>
<title><![CDATA[Journal of Dentistry Indonesia (Vol. 29, No.3 December 2022)]]></title>
</titleInfo>
<name type="Personal Name" authority="">
<namePart>Universitas Indonesia</namePart>
<role><roleTerm type="text">Pengarang</roleTerm></role>
</name>
<typeOfResource manuscript="yes" collection="yes"><![CDATA[mixed material]]></typeOfResource>
<genre authority="marcgt"><![CDATA[bibliography]]></genre>
<originInfo>
<place><placeTerm type="text"><![CDATA[]]></placeTerm></place>
<publisher><![CDATA[]]></publisher>
<dateIssued><![CDATA[2022]]></dateIssued>
<issuance><![CDATA[monographic]]></issuance>
<edition><![CDATA[0]]></edition>
</originInfo>
<language>
<languageTerm type="code"><![CDATA[en]]></languageTerm>
<languageTerm type="text"><![CDATA[English]]></languageTerm>
</language>
<physicalDescription>
<form authority="gmd"><![CDATA[]]></form>
<extent><![CDATA[21 x 29 cm ; 239 Hal]]></extent>
</physicalDescription>
<note>ABSTRACT
Objective: Root canal anatomy significantly impacts the working length determination. This study aimed to
investigate the effect of the preflaring technique on the accuracy of four electronic apex locators. Methods:
Forty-five single-canal central maxillary teeth were selected. The working length was measured before and after
the coronal preparation by four types of electronic apex locators in the range of ±0.5 and ±1 mm matched for the
apical constriction. The actual working length was calculated under a microscope. Data were analyzed using ICC
and paired t-tests in SPSS16. A p < 0.05 was considered significant. Results: The accuracies of Root ZX, DTE,
Denjoy, and Coxo apex locators in the range of ± 0.05 mm were 71.1, 93.3, 84.4, and 75.6% before preflaring, and
82.2, 93.3, 97.8, and 100% after that. The corresponding values in the range of ±1 mm were 86.7, 97.8, 93.3, and
100% before and 97.8, 100, 100, and 100% after preflaring. Significant differences were found between the working
lengths measured by the four devices and the actual working lengths before and after preflaring. Conclusion: The
preflaring technique could impact the performance of apex locators in determining the working length and may
be advocated for better outcomes</note>
<subject authority=""><topic><![CDATA[Keperawatan Gigi]]></topic></subject>
<classification><![CDATA[040 JI. JOU j(29) /3 2022]]></classification><identifier type="isbn"><![CDATA[16939697/23554800]]></identifier><location>
<physicalLocation><![CDATA[REPOSITORY Politeknik Kesehatan Kemenkes Jakarta I]]></physicalLocation>
<shelfLocator><![CDATA[040 JI. JOU j(29) /3 2022]]></shelfLocator>
<holdingSimple>
<copyInformation>
<numerationAndChronology type="1"><![CDATA[T202240]]></numerationAndChronology>
<sublocation><![CDATA[Rak Jurusan Kesehatan Gigi Poltekkes Kemenkes Jakarta I (040 JI. JOU 2022)]]></sublocation>
<shelfLocator><![CDATA[040 JI. JOU j(29) /3 2022]]></shelfLocator>
</copyInformation>
</holdingSimple>
</location>
<slims:image><![CDATA[vol_29.3-29.jpg.jpg]]></slims:image>
<recordInfo>
<recordIdentifier><![CDATA[3534]]></recordIdentifier>
<recordCreationDate encoding="w3cdtf"><![CDATA[2025-02-11 09:22:57]]></recordCreationDate>
<recordChangeDate encoding="w3cdtf"><![CDATA[2025-02-25 11:09:26]]></recordChangeDate>
<recordOrigin><![CDATA[machine generated]]></recordOrigin>
</recordInfo></mods></modsCollection>