<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" ID="3532">
<titleInfo>
<title><![CDATA[Journal of Dentistry Indonesia (Vol. 29, No.1 April 2022)]]></title>
</titleInfo>
<name type="Personal Name" authority="">
<namePart>Universitas Indonesia</namePart>
<role><roleTerm type="text">Pengarang</roleTerm></role>
</name>
<typeOfResource manuscript="yes" collection="yes"><![CDATA[mixed material]]></typeOfResource>
<genre authority="marcgt"><![CDATA[bibliography]]></genre>
<originInfo>
<place><placeTerm type="text"><![CDATA[]]></placeTerm></place>
<publisher><![CDATA[]]></publisher>
<dateIssued><![CDATA[2022]]></dateIssued>
<issuance><![CDATA[monographic]]></issuance>
<edition><![CDATA[0]]></edition>
</originInfo>
<language>
<languageTerm type="code"><![CDATA[en]]></languageTerm>
<languageTerm type="text"><![CDATA[English]]></languageTerm>
</language>
<physicalDescription>
<form authority="gmd"><![CDATA[]]></form>
<extent><![CDATA[21 x 29 cm ; 61 Hal]]></extent>
</physicalDescription>
<note>ABSTRACT
Objectives: This study aimed to compare the surface roughness of three anterior composite resins with different
filler size, rate, and shape after brushing for 5000, 10000, and 20000 cycles with a whitening dentifrice.Methods: 44
disk-shaped specimens of each material (5mm diameter, 2mm depth) G-aenial Anterior, Harmonize, Asteria were
prepared and divided into four groups according to the brushing cycles (Initial, 5000, 10000, and 20000 cycles).
Initial surface roughness values (Ra-values) were assessed using a profilometer and measurements were repeated
after each brushing cycle. 4 specimens from each composite resin were observed by scanning electron microscopy
before and after brushing. The data were analyzed by Shapiro Wilk., ANOVA, Tukey, Friedman, and Wilcoxon
tests (p<0.05). Results: The Ra-values of all groups increased in proportion to the number of brushing cycles
(p<.05). The Ra-values of both Asteria and Harmonize were significantly lower than the G-aenial after all brushing
cycles (p<0.05). Conclusion: All of the materials demonstrated surface irregularities after 20.000 brushing cycles
corresponding to 24 months. The degree of surface alteration increased with brushing time and depends on the
composite’s filler rate, size, and shape</note>
<subject authority=""><topic><![CDATA[Keperawatan Gigi]]></topic></subject>
<classification><![CDATA[038 JI. JOU j(29) /1 2022]]></classification><identifier type="isbn"><![CDATA[16939697/23554800]]></identifier><location>
<physicalLocation><![CDATA[REPOSITORY Politeknik Kesehatan Kemenkes Jakarta I]]></physicalLocation>
<shelfLocator><![CDATA[038 JI. JOU j(29) /1 2022]]></shelfLocator>
<holdingSimple>
<copyInformation>
<numerationAndChronology type="1"><![CDATA[T202238]]></numerationAndChronology>
<sublocation><![CDATA[Rak Jurusan Kesehatan Gigi Poltekkes Kemenkes Jakarta I (038 JI. JOU 2022)]]></sublocation>
<shelfLocator><![CDATA[038 JI. JOU j(29) /1 2022]]></shelfLocator>
</copyInformation>
</holdingSimple>
</location>
<slims:image><![CDATA[Caper_april_22-1.jpg.jpg]]></slims:image>
<recordInfo>
<recordIdentifier><![CDATA[3532]]></recordIdentifier>
<recordCreationDate encoding="w3cdtf"><![CDATA[2025-02-11 09:03:42]]></recordCreationDate>
<recordChangeDate encoding="w3cdtf"><![CDATA[2025-02-25 10:55:46]]></recordChangeDate>
<recordOrigin><![CDATA[machine generated]]></recordOrigin>
</recordInfo></mods></modsCollection>