<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" ID="3531">
<titleInfo>
<title><![CDATA[Journal of Dentistry Indonesia (Vol. 28, No.3 December 2021)]]></title>
</titleInfo>
<name type="Personal Name" authority="">
<namePart>Universitas Indonesia</namePart>
<role><roleTerm type="text">Pengarang</roleTerm></role>
</name>
<typeOfResource manuscript="yes" collection="yes"><![CDATA[mixed material]]></typeOfResource>
<genre authority="marcgt"><![CDATA[bibliography]]></genre>
<originInfo>
<place><placeTerm type="text"><![CDATA[]]></placeTerm></place>
<publisher><![CDATA[]]></publisher>
<dateIssued><![CDATA[2021]]></dateIssued>
<issuance><![CDATA[monographic]]></issuance>
<edition><![CDATA[0]]></edition>
</originInfo>
<language>
<languageTerm type="code"><![CDATA[en]]></languageTerm>
<languageTerm type="text"><![CDATA[English]]></languageTerm>
</language>
<physicalDescription>
<form authority="gmd"><![CDATA[]]></form>
<extent><![CDATA[21 x 29 cm ; 204 Hal]]></extent>
</physicalDescription>
<note>ABSTRACT
Objectives: The purpose of this study was to compare high viscosity glass ionomer cement (HVGIC), giomer and
microhybrid composite using the atomic force microscopy (AFM) and Vickers microhardness. Methods: Three
different restorative materials Equia Forte (HVGIC), Beautifil II (giomer) and Solare X (microhybrid composite)
were used in this study. A total of 30 samples were prepared, 10 of each of the restorative materials used in our
study. Samples were prepared using standard cylindrical Teflon molds with a diameter of 8 mm and a height
of 2 mm. The measurements of surface roughness and hardness were performed by using AFM and Vickers
microhardness, respectively. The surface roughness was analyzed using the Kruskal Wallis test. One-way variance
analysis (ANOVA) and LSD test was used for the surface hardness (α = 0.05). Results: There was no significant
difference between the groups according to surface roughness values (p> 0.05). A statistically significant difference
was found between all groups in terms of surface hardness. Conclusion: Reinforced glass ionomer cements had
similar and surface properties than composite resin</note>
<subject authority=""><topic><![CDATA[Keperawatan Gigi]]></topic></subject>
<classification><![CDATA[037JI. JOU j(28) 3 / 2021]]></classification><identifier type="isbn"><![CDATA[16939697/23554800]]></identifier><location>
<physicalLocation><![CDATA[REPOSITORY Politeknik Kesehatan Kemenkes Jakarta I]]></physicalLocation>
<shelfLocator><![CDATA[037JI. JOU j(28) 3 / 2021]]></shelfLocator>
<holdingSimple>
<copyInformation>
<numerationAndChronology type="1"><![CDATA[T202137]]></numerationAndChronology>
<sublocation><![CDATA[Rak Jurusan Kesehatan Gigi Poltekkes Kemenkes Jakarta I (037 JI. JOU 2021)]]></sublocation>
<shelfLocator><![CDATA[037 JI. JOU j(28) 3 / 2021]]></shelfLocator>
</copyInformation>
</holdingSimple>
</location>
<slims:image><![CDATA[coy-28.jpg.jpg]]></slims:image>
<recordInfo>
<recordIdentifier><![CDATA[3531]]></recordIdentifier>
<recordCreationDate encoding="w3cdtf"><![CDATA[2025-02-11 08:24:18]]></recordCreationDate>
<recordChangeDate encoding="w3cdtf"><![CDATA[2025-02-25 10:52:05]]></recordChangeDate>
<recordOrigin><![CDATA[machine generated]]></recordOrigin>
</recordInfo></mods></modsCollection>